Lithium Ion Risk Prevention Syste

Fire Detection Systems

Johnson Controls Lithium Ion Risk Prevention System is an early detection solution designed to improve safety in Energy Storage Systems (ESS) and lithium-ion battery installations. The system monitors the air around battery racks and detects off-gases or toxic vapors released during the early stages of battery cell failure.

Early detection helps identify abnormal battery conditions before a thermal runaway event occurs. This allows operators to take preventive action before the failure develops into a fire or a serious safety incident.

The Lithium Ion Risk Prevention System detects very small changes in air composition around lithium-ion batteries. The system provides early warning detection so operators can respond quickly to potential battery failures.

The system can also integrate with Battery Management Systems (BMS), fire detection systems, and fire suppression systems from Johnson Controls. This integration provides comprehensive protection for energy storage facilities, data centers, and lithium-ion battery installations.

Key Features

  • Early detection of off-gases or toxic vapors from lithium-ion batteries.

  • Provides early warning detection before thermal runaway occurs.

  • Response time of approximately 5 seconds to detect air composition changes around battery systems.

  • Uses two monitoring sensors:

    • Reference sensor to monitor ambient air conditions.

    • Monitoring sensor installed inside battery racks to detect off-gas directly.

  • Integrates with AutoPulse, ZETTLER, and FIRECLASS fire detection systems.

  • Compatible with Inergen® and SAPPHIRE Fire Suppression Systems.

  • Patent-pending technology from Johnson Controls.

Detection Technology
Off-gas detection system designed to monitor lithium-ion battery conditions and detect early signs of battery cell failure.

Response Time
Approximately 5 seconds detection response time.

Monitoring Sensors
The system uses two types of sensors:

  • Reference Sensormonitors ambient air conditions around the battery environment.

  • Monitoring Sensorinstalled inside the battery rack to detect off-gas released from lithium-ion batteries.

Detection Capability
Capable of detecting very small changes in air composition, including lithium-ion off-gas compounds at levels below 1 ppm.

System Integration

  • Battery Management System (BMS)

  • AutoPulse Fire Detection System

  • ZETTLER Fire Detection System

  • FIRECLASS Fire Detection System

  • Inergen® Fire Suppression System

  • SAPPHIRE Fire Suppression System

  • Wind farms

  • Solar farms

  • Data centers

  • Battery storage rooms

  • Battery manufacturing facilities

  • Engineering, Procurement, and Construction (EPC) projects